Análise experimental de pilares de concreto armado sob ação centrada com resistência do concreto de 25 MPa

dc.contributorGiongo, José Samuel
dc.creatorRamos, Ricardo Ferreira
dc.date2001-07-31
dc.date2016-08-12
dc.date.accessioned2017-11-15T11:25:12Z
dc.date.available2017-11-15T11:25:12Z
dc.date.issued2017-11-15
dc.descriptionEste trabalho analisou o comportamento teórico e experimental de pilares de concreto armado submetidos à força de compressão centrada e executados com concreto de resistência à compressão em torno de 25 MPa. Durante a fase experimental, foram ensaiados 16 modelos com dimensões das seções transversais de 200 mm x 200 mm e 150 mm x 300 mm, sendo as alturas iguais a seis vezes a menor dimensão da seção, ou seja, 1200 mm e 900 mm, respectivamente. Além das dimensões dos pilares, outros parâmetros foram considerados, tais como a taxa de armadura longitudinal e o espaçamento e a configuração da armadura transversal. Os ensaios foram realizados em uma máquina hidráulica servo-controlada que permitiu aplicar a força de compressão com controle de deslocamento. Assim, foi possível obter o trecho pós-pico da curva força-deformação dos pilares. Os resultados experimentais mostraram que não há formação de núcleo resistente. Foi notado que as fissuras surgiram em etapa de carga muito próxima do colapso dos modelos. Para as taxas de armadura transversal adotadas, foi verificado um ligeiro cintamento e um expressivo aumento na ductilidade dos pilares. Por fim, verificou-se que o estribo suplementar, em forma de barra reta com ganchos nas extremidades contribuiu para cintar e ductilizar os modelos de pilares.
dc.descriptionThis work analysed the theoretical and experimental behaviour of reinforced concrete columns under axial compression force with concrete compressive strenght around of 25 MPa. In the experimental stage it was tested 16 specimens with cross sections of 200 mm x 200 mm and 150 mm x 300 mm. The height of the columns were six times the smallest dimension of the cross section, i.e., 1200 mm and 900 mm, respectively. Besides the dimensions of the columns, other parameters, like longitudinal reinforcement ratio and the spacing and arrangement of the transverse reinforcement were varied. The columns were loaded concentrically in an servohidraulically controlled testing machine that permitted applying the compression force with displacement control. Therefore, it was possible to obtain the force-strain curve post-peak. The results showed that were not formed resistent cores. Cracks appeared in a load stage near the failure of the specimens. For the transversal reinforcement ratio adopted, it was verified a small gain in strength and an significant increase in ductility. At last, the supplementary cross ties provided gain of strength and ductility in the columns.
dc.formatapplication/pdf
dc.identifierhttp://www.teses.usp.br/teses/disponiveis/18/18134/tde-12082016-115720/
dc.identifierdoi:10.11606/D.18.2016.tde-12082016-115720
dc.identifier.urihttp://repositorio.eesc.usp.br/handle/RIEESC/5216
dc.languagept
dc.publisherBiblioteca Digital de Teses e Dissertações da USP
dc.publisherUniversidade de São Paulo
dc.publisherEscola de Engenharia de São Carlos
dc.rightsLiberar o conteúdo para acesso público.
dc.subjectConcreto armado
dc.subjectExperimentação
dc.subjectPilares
dc.subjectColumns
dc.subjectReinforced concrete
dc.subjectTests
dc.titleAnálise experimental de pilares de concreto armado sob ação centrada com resistência do concreto de 25 MPa
dc.titleExperimental analysis of reinforced concrete columns under axial force with concrete strength of 25 MPa
dc.typeDissertação de Mestrado